您好,欢迎来到爱问旅游网。
搜索
您的当前位置:首页重复性再现性自动生成表格

重复性再现性自动生成表格

来源:爱问旅游网
量具重复性和再现性分析报告(非破坏性试验)以公差为基础进行分析以过程变差为基础进行分析参数设定K1测量次数K2评价人数量K3零件数量Out of UCLr'01 PSW'01 PSW'!A6'01 PSW'!A21'01 PSW'!A参数设定状况结论必须是2或3必须是2或3大于等于2,小于等于10 A2 B4 B5 C2 C4 C5 C9'01 PSW'!H3310OKOKOK测量系统需改进,极差 A2B4 B5 C2 C4 C5 C9超出范围需对测量人员进行分析零件编号:测量项目:公差范围:总变差(TV):评价人/测量次数A123平均值极差B123平均值极差C123平均值极差零件平均值3502572-AOLES孔径0.280.03791规格:单位:Φ23.5 +0.28/0mm零件名称:后制动鼓量具编号:WJ0190-1量具名称:游标卡尺量具精度:0.02零件 公司名称:电话:批准:日期:2012.04.12123.6023.6023.6023.600.00223.6623.6823.6623.670.02323.6823.6823.6823.680.00423.7023.7023.7023.700.00523.6623.6623.6623.660.00623.6823.6823.6823.680.00723.6823.6823.6823.680.00823.6823.6823.6823.680.00923.6823.6823.6823.680.001023.7223.7223.7223.720.00平均值A1A2A3XARA23.6740023.6760023.6740023.674670.0020023.6760023.6750023.6780023.676330.0050023.6760023.6790023.6750023.676670.0100023.6750.120000.005670.002000.0146223.6023.6023.6023.600.0023.6623.6623.6623.660.0023.6823.6923.6823.680.0123.7223.7023.7223.710.0223.6623.6623.6823.670.0223.6823.6823.6823.680.0023.6823.6823.6823.680.0023.6823.6823.6823.680.0023.6823.6823.6823.680.0023.7223.7223.7223.720.00B1B2B3XBRB23.6023.6023.6023.60.023.600023.6623.6823.6623.666670.0223.23.6823.6823.6923.683330.0123.682223.7023.7223.7023.706670.0223.706723.6623.6823.6623.666670.0223.23.6823.6823.6823.680.023.680023.6923.6823.6823.683330.0123.681123.6823.6823.6823.680.023.680023.6923.6723.6823.680.0223.680023.7223.7223.7223.720.023.7200C1C2C3XCRCxP =RP =极差R =(RA+ RB + RC)/ 评价人数量 =(XDIFF=[Max (X)ABC] - [Min (X)ABC] =0.0020023.676670.00567姓名ABC+-*0.0050023.674672.580+0.01000)/3==UCLR=评价人ABCR*D4 ==测量单元分析重复性—设备变差(EV)EV =R * K1 =0.00335再现性—评价人变差(AV)AV= ( XDIFF * K2)2 - (EV2 / (nr))=0.00085(n=零件数量,r=测量次数)重复性和再现性(GRR)GRR= (EV2 + AV2)=0.00345零件变差(PV)PV=RP * K3=总变差(TV)TV= (GRR2 + PV2)=0.03791极差图0.03775总变差%(TV)试验次数23评价人数33K10.88620.5908K20.52310.5231% EV =100[EV/TV]=8.83%% AV =100[AV/TV]=2.24%% GRR =100[GRR/TV]=9.11%零件数量10K30.31460.3146区别分类数(ndc)% PV =100[PV/TV]=99.58%ndc=1.41*PV/GRR=15量具重复性和再现性分析报告(非破坏性试验)以公差为基础进行分析以过程变差为基础进行分析参数设定K1测量次数K2评价人数量K3零件数量Out of UCLr'01 PSW'01 PSW'!A6'01 PSW'!A21'01 PSW'!A参数设定状况结论必须是2或3必须是2或3大于等于2,小于等于10 A2 B4 B5 C2 C4 C5 C9'01 PSW'!H3310OKOKOK测量系统需改进,极差 A2B4 B5 C2 C4 C5 C9超出范围需对测量人员进行分析零件编号:测量项目:公差范围:总变差(TV):3502572-AOLES孔径0.280.03791规格:单位:Φ23.5 +0.28/0mm零件名称:后制动鼓量具编号:WJ0190-1量具名称:游标卡尺量具精度:0.02极差图公司名称:电话:批准: 日期:2012.04.120.03 0.02 0.02 0.01 0.01 0.00 1234ABUCLRR5C6UCLR7R10均值图23.74 23.72 23.70 23.68 23.66 23. 23.62 23.60 23.58 23.56 23. 1234567AUCLLCL8B9C10UCLLCL测量系统可接受性的通用比例原则:·%GRR低于10%的误差—可接受的测量系统·%GRR在10%到30%的误差—根据应用的重要性、测量装置的成本、维修费用等, 可能是可接受的。·%GRR大于30%的误差—不可接受,应尽各种力量以改进这测量系统。·区别分类数(ndc)要大于或等于5。极差图评价:·若所有的极差均受控,则说明所有评价人都进行了相同的工作。·若某个评价人是在控制限之外,则说明他使用的方法与其他人不一致。·若所有评价人均有一些超出控制范围的点,则说明该测量系统对评价人的技巧较较敏感,需要进行改进以获得有效的数据。均值图评价:·大约一半或一半以上的数据点落在控制限之外,则测量系统是适合进行检验出零件之间的变差,以及能为过程的分析和控制提供有用的信息·若少于一半的数据点落在控制限之外,则测量系统的有效分辨率不足,或者样本不能代表预期的过程变差。备注:

因篇幅问题不能全部显示,请点此查看更多更全内容

Copyright © 2019- awee.cn 版权所有 湘ICP备2023022495号-5

违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com

本站由北京市万商天勤律师事务所王兴未律师提供法律服务